Abstract
Abstract:
Experimental study about correlation between concentrations of soot and NOx in combustion products of industrial furnace using DO is carried out thanks to the Visioscope and Gas Analyzer Diagas AVL. The results show that temperature of combustion chamber and mixture equivalent ratio have important effect on soot and NOx concentrations. High temperature is the cause of a simultaneous increase in soot and NOx formation speeds whereas equivalent ratio gives inverse evolution of these two values.